What it means

Access to the FROM (flash memory) timed out - the CPU issued a read/write to flash memory and got no response within the allotted time. Fanuc's procedure: replace the FROM/SRAM module first; if the alarm persists, replace the main board. Since FROM holds the system software, this alarm often prevents normal boot.

Likely causes

  • FROM/SRAM module failure or poor seating
  • Main board flash interface fault

Triage note: Back up SRAM/part programs before touching the FROM/SRAM module.