RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 500

Fanuc alarm 500: SRAM DATA ERROR (SRAM MODULE)

30i/31i/32i system alarm · Fanuc 30i/31i/32i-B

What it means

Data integrity checking found corrupted contents in the SRAM on the FROM/SRAM module. Fanuc notes this frequently happens when the backup battery voltage dropped or the LCD-mounted unit was powered with its case removed, which is not a hardware failure - in that case replace the battery, refit the case, then perform a full memory clear and reload. Otherwise replace the FROM/SRAM module and finally the main board.

Likely causes

  • Low or dead SRAM backup battery (check first)
  • Unit operated without its case/cover fitted
  • Genuine FROM/SRAM module failure

Triage note: Memory all-clear erases parameters and programs - restore from a known-good backup afterwards.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 500 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog