RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 51

Fanuc alarm 51

αi SPM · Fanuc αi SPM

What it means

DC link undervoltage reported on SPM; actual source normally the converter.

Likely causes

  • PSM alarm 04 condition mirrored: supply dip / low input voltage
  • Loose DC link bus bars between modules

Triage note: Combo rule: SPM 51 with PSM 4 = troubleshoot PSM/supply. CNC: SP0051 / 9051.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • DC link bus bar / short bar set

    DC Link Bus Bar · Common cause

    Request a quote →
  • A06B-6087-H126

    Power Supply Module αi PSM (only if PSM confirms alarm 04 internally) · Check if others ruled out

    View part →

Need the part urgently?

Send us alarm 51 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog