Fanuc alarm 55: Switching request/state mismatch during motor activation

αi SPM · Fanuc αi SPM

What it means

In αi spindle-switching or output-switching control, the mismatch between the switching request signal (SPSL/RSL) and the power-lead state check signal persisted while the motor was active. The drive refuses to run in an undefined switching state.

Likely causes

  • Power-lead switching magnetic contactor faulty
  • Contact-check I/O wiring defective
  • Ladder performs switching during motor activation (not permitted)

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 55 with your machine details — typical RFQ turnaround is 24–48h.