RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / 8

Fanuc alarm 8

αi SVM · Fanuc αi SVM

What it means

Inverter: DC link current alarm, L axis (first axis on multi-axis SVM).

Likely causes

  • Short circuit between power lead phases or ground fault in power leads
  • Short circuit between motor winding phases or winding-to-ground fault
  • SVM inverter failure (IGBT shorted)

Triage note: B-65285EN 3.2.7 isolation: disconnect motor leads; alarm persists with leads off = SVM; alarm clears = megger leads then motor. Companion CNC alarms SV0600 detail 8.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 8 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog