Fanuc alarm 90: Unexpected rotation detected
αi SPM · Fanuc αi SPM
What it means
The αi SPM detected a rotation state in which the torque-command polarity disagrees with the direction of acceleration, issued for BiS synchronous spindle motors. Often follows mechanical shock to the spindle that shifted the sensor-to-rotor phase relationship.
Likely causes
- Motor sensor tooth count / phase parameter setting error
- AMR offset parameters (No. 4084/4085) need readjustment after sensor or shaft slippage
- Motor-sensor count errors due to noise
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
Motor sensor ring (if slippage confirmed)
amplifier · Common cause
Need the part urgently?
Send us alarm 90 with your machine details — typical RFQ turnaround is 24–48h.