Fanuc alarm 90: Unexpected rotation detected

αi SPM · Fanuc αi SPM

What it means

The αi SPM detected a rotation state in which the torque-command polarity disagrees with the direction of acceleration, issued for BiS synchronous spindle motors. Often follows mechanical shock to the spindle that shifted the sensor-to-rotor phase relationship.

Likely causes

  • Motor sensor tooth count / phase parameter setting error
  • AMR offset parameters (No. 4084/4085) need readjustment after sensor or shaft slippage
  • Motor-sensor count errors due to noise

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 90 with your machine details — typical RFQ turnaround is 24–48h.