Fanuc alarm 960: SUB CPU ERROR / DC24V POWER OFF

system alarm · Fanuc 0i-D

What it means

An illegal interrupt occurred in the sub-CPU section of the control - an interrupt that should never arise under normal execution. On multi-processor controls this points to the sub-CPU board or its peripheral circuits; Fanuc's own troubleshooting also flags abnormal 24 VDC input power as a possible trigger. If power cycling restores normal operation once, suspect electrical noise; recurrence condemns the sub-CPU hardware.

Likely causes

  • Sub-CPU printed circuit board defective
  • Abnormal or noisy 24VDC control power feed
  • Electrical noise (poor earthing, missing surge suppression)

Triage note: Only present on configurations that use a sub-CPU (e.g. multi-path/large systems). Verify 24VDC quality before board replacement.