What it means

On the αi power supply module (PSM / αiPS), a fan mounted on the external radiator cooling fin has stopped. On A06B-6110/A06B-6120 series units this code is also issued when the internal unit stirring fan stops. The ALM LED lights red with 'A' on the 7-segment STATUS display.

Likely causes

  • Radiator cooling-fin fan seized or blocked by debris
  • Unit stirring fan failed (A06B-6110-Hxxx / A06B-6120-Hxxx)
  • Fan connector loose or faceplate (control PCB) not fully seated

Triage note: Warning-code variant of A may blink before the alarm latches; module stays operable while warning shows.