Fanuc alarm A
αi SVM · Fanuc αi SVM
What it means
Inverter: DC link current alarm, H/N axis (third axis; never valid on 1-2 axis units).
Likely causes
- Power lead short or ground fault
- Motor winding short / ground fault
- SVM inverter failure
Triage note: CNC alarm SV0600 detail A. If displayed on a 2-axis SVM, suspect the SVM itself.