αi SVM · Fanuc αi SVM

What it means

Inverter: motor current alarm (L axis) - abnormal motor current detected via current feedback.

Likely causes

  • Short circuit / ground fault in power leads
  • Motor winding short / insulation breakdown
  • Incorrect motor ID setting or overly aggressive acc/dec (parameters 2004/2040/2041 group)
  • SVM or motor failure

Triage note: CNC alarm SV0438 detail b. Check default parameters and lengthen acc/dec if alarm occurs only on rapid reversal before condemning hardware.