RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / F

Fanuc alarm F

αi SVM · Fanuc αi SVM

What it means

Inverter: cooling fan stopped of the radiator (external heat-sink fan).

Likely causes

  • Radiator fan failed or obstructed
  • Fan motor connector or cable defective
  • Control PCB not fully seated
  • SVM fan-drive circuit failure

Triage note: Warning state first (CNC DS0609), escalates to hard alarm SV0601 within about a minute taking all axes down. Highest-frequency alpha i SVM field failure after IPM faults.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Per-module radiator fan kit

    Cooling Fan Assembly · Primary suspect

    Request a quote →
  • A06B-6114-H2xx

    Servo Amplifier Module αiSVM (rating-dependent, if new fan does not clear) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm F with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog