What it means

Inverter: FSSB fiber communication error on COP10A side - slave-direction link failure.

Likely causes

  • COP10A optical fiber cable failure (farthest affected unit)
  • SVM COP10A interface failure
  • Downstream SVM failure

Triage note: Section 3.2.13: replace COP10A cable farthest from CNC first, then offending SVM. Dirty/bent fiber tips are a common non-part cause - clean before ordering.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • COP10A FSSB optical fiber cable

    FSSB Optical Fiber Cable · Primary suspect

    Request a quote →
  • A06B-6114-H2xx

    Servo Amplifier Module αiSVM (unit farthest from CNC showing L) · Common cause

    Request a quote →