Fanuc alarm OT0500: OVER TRAVEL: +n

overtravel alarm · Fanuc 0i-D

What it means

Stored stroke limit exceeded in positive direction (OT0501 = negative) - soft limit hit

Likely causes

  • lost reference position (crash, e-stop mid-travel, battery-dead axis)
  • wrong work/offset shift
  • genuine jog past soft limit

Triage note: Usually NO parts needed: jog out with limit-release or redo reference return; if axis keeps losing position, chase SV0300/battery instead

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A02B-0200-K102

    Battery Unit (if axis lost absolute position) · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm OT0500 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog