Fanuc alarm P
αi SVM · Fanuc αi SVM
What it means
Communication error between amplifier and module (internal inter-module link CXI/CXA2).
Likely causes
- CXA2A/CXA2B connector or cable defective
- SVM control printed-circuit board failure
- Adjacent module (PSM/SPM) communication-side failure
Triage note: CNC alarm SV0604. Swap-test cable before boards; on beta i SVPM the same fault shows STATUS2 'P'.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A06B-6114-K220
CXA2 inter-module connector/cable (catalog item) · Common cause
- Request a quote →
SVM control PCB per module
Amplifier Control Board · Common cause
- Request a quote →
A06B-6114-H2xx
Servo Amplifier Module αiSVM · Check if others ruled out