RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / PS000

Fanuc alarm PS000: PLEASE TURN OFF POWER

system alarm · Fanuc 0i-D

What it means

The classic power-up-class P/S alarm: a parameter whose new value only takes effect after a reboot has been changed, and the CNC holds this alarm until the control is switched off and on again. It is informational rather than a fault - the machine stays alarmed purely to force the power cycle.

Likely causes

  • Servo/spindle/system parameter edited that requires restart
  • Parameter restored from backup containing such changes
  • PMC or option setting changed via G10/parameter screen

Triage note: Not a hardware fault: complete your parameter edits, then power the control off/on. If it reappears without edits, check for a PMC sequence writing parameters at startup.

Need the part urgently?

Send us alarm PS000 with your machine details — typical RFQ turnaround is 24–48h.