What it means

A decimal point was used at an address that does not accept one, or two decimal points were specified within one word. Integer-only addresses reject decimal notation.

Likely causes

  • Decimal point on an integer address (e.g. G, M, sequence numbers)
  • Two decimal points typed in one word
  • CAM post-processor outputting decimals on wrong addresses