Fanuc alarm PS0045: ADDRESS Q NOT FOUND (G73/G83)

PS alarm (program/operation) · Fanuc 0i-D

What it means

In the high-speed peck (G73) or deep-hole peck (G83) drilling cycles, the per-peck cutting depth Q was not specified or Q0 was commanded. Q defines each incremental cut and is mandatory for those cycles.

Likely causes

  • Q word omitted in the G73/G83 block
  • Q specified as zero
  • Wrong cycle chosen for the available words