Fanuc alarm PS0045: ADDRESS Q NOT FOUND (G73/G83)
PS alarm (program/operation) · Fanuc 0i-D
What it means
In the high-speed peck (G73) or deep-hole peck (G83) drilling cycles, the per-peck cutting depth Q was not specified or Q0 was commanded. Q defines each incremental cut and is mandatory for those cycles.
Likely causes
- Q word omitted in the G73/G83 block
- Q specified as zero
- Wrong cycle chosen for the available words