RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / PS0050

Fanuc alarm PS0050: CHF/CNR NOT ALLOWED IN THRD BLK

PS alarm (program/operation) · Fanuc 0i-D

What it means

Chamfering (C) or corner R was specified in a threading block. These corner-treatment words are not permitted together with thread cutting commands.

Likely causes

  • Chamfer/corner-R word left in a G32/G92 threading block
  • Converted lathe program retaining chamfer words

Need the part urgently?

Send us alarm PS0050 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog