Fanuc alarm PS0122: TOO MANY MACRO NESTING

PS alarm (program/operation) · Fanuc 0i-D

What it means

Custom-macro calls (G65/G66) were nested beyond the permitted depth. The call chain must be flattened or split.

Likely causes

  • Recursive G65 calls without termination
  • Deeply layered library macros