Fanuc alarm SP1975: ANALOG SPINDLE CONTROL ERROR

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

An abnormality was detected in the position coder of an analog spindle system. Even where the spindle drive itself is analog, the CNC monitors the position coder used for orientation/threading; a fault in that feedback path triggers this CNC-side alarm.

Likely causes

  • Position coder cable disconnected or damaged
  • Coder head failure or contaminated disk
  • Incorrect coder-related parameter selection

Replacement parts