Fanuc alarm SP9003: SERIAL SPINDLE AL03: DC LINK FUSE BLOWN

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

SPM reports DC-link fuse blown (voltage insufficient at fuse check on e-stop release)

Likely causes

  • SPM power stage short (IGBT)
  • spindle motor insulation failure
  • magnetizing inrush from failed switching/windings

Triage note: Insulation-check the spindle motor BEFORE installing the new SPM; a grounded motor will blow the replacement's fuse at first start

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SP9003 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog