Fanuc alarm SP9007: SSPA:07 OVER SPEED

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

Motor speed exceeded the permissible maximum (about 115% of the rated value), or accumulated position deviation indicated runaway motion. The amplifier halts output immediately to protect the rotor and bearings.

Likely causes

  • Erratic speed command from the CNC or PMC
  • Speed feedback loss or corruption causing false overspeed
  • Wrong motor model or maximum speed parameters after a swap
  • Regenerative braking failure letting speed run away during deceleration

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6120-Hxxx

    alpha i Spindle Amplifier Module (SPM) · Check if others ruled out

    Request a quote →