Fanuc alarm SP9012: SERIAL SPINDLE AL12: DC LINK OVERCURRENT

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

Excessive current sensed in SPM DC link - power semiconductor or motor short

Likely causes

  • SPM transistor/IPM failure
  • spindle motor winding short
  • incorrect motor initialization parameters
  • winding-switch contactor timing fault

Triage note: Confirm motor insulation and phase sequence first; alarm immediately at excitation with good motor = SPM replacement

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6202-H222

    Spindle Amplifier Module (alpha iSP SPM) · Primary suspect

    Request a quote →
  • A06B-6222-B100

    Built-in Spindle Motor (check megger) · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm SP9012 with your machine details — typical RFQ turnaround is 24–48h.