RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SP9015

Fanuc alarm SP9015: SSPA:15 SP SWITCH CONTROL ALARM

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

In machines with spindle switching or output switching contactors, the actual contactor status signal did not match the commanded state within the allowed time. The amplifier aborts the switch-over because running across a half-switched gear/output stage would destroy hardware.

Likely causes

  • Contactor coil failure or welded/sticking contacts
  • Auxiliary contact feedback wiring fault
  • PMC switch-over ladder timing too slow
  • Wrong spindle switching parameters

Need the part urgently?

Send us alarm SP9015 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog