RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SP9019

Fanuc alarm SP9019: SERIAL SPINDLE AL19: EXCESSIVE U-PHASE CURRENT OFFSET

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

Initial value of U-phase current detection circuit out of range at power-up (AL20 = V-phase)

Likely causes

  • SPM current-detection circuit drift/failure
  • loose connector between power unit and control PCB after service
  • control PCB failure

Triage note: Reseat the power-unit-to-control-PCB connectors first if the alarm appeared after board service; otherwise SPM exchange

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SP9019 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog