Fanuc alarm SP9020: SSPA:20 EX OFFSET CURRENT V (SPM FAULTY)
spindle alarm (serial spindle, alpha i) · Fanuc 0i-D
What it means
The offset of the V-phase current detection circuit drifted beyond the permissible range. The amplifier self-checks current-sensor zero points at power-up; a V-phase offset error means the phase current feedback can no longer be trusted for torque control.
Likely causes
- Failed current detector circuitry on the SPM
- Control board component drift with age/heat
Triage note: Companion alarm to the U-phase variant.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A06B-6120-Hxxx
alpha i Spindle Amplifier Module (SPM) · Primary suspect
Need the part urgently?