RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SP9020

Fanuc alarm SP9020: SSPA:20 EX OFFSET CURRENT V (SPM FAULTY)

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

The offset of the V-phase current detection circuit drifted beyond the permissible range. The amplifier self-checks current-sensor zero points at power-up; a V-phase offset error means the phase current feedback can no longer be trusted for torque control.

Likely causes

  • Failed current detector circuitry on the SPM
  • Control board component drift with age/heat

Triage note: Companion alarm to the U-phase variant.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SP9020 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog