RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SP9030

Fanuc alarm SP9030: OVERCURRENT (PSM FAULTY)

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

Overcurrent was detected in the input/converter circuit of the power supply module. The PSM's protection tripped because current through its power devices exceeded safe limits, indicating an internal power-stage fault or a downstream short.

Likely causes

  • Failed IPM/transistor stack in the PSM
  • DC link short or damaged capacitor bank
  • Ground fault in attached spindle/servo circuits

Triage note: Check insulation of the whole drive train before powering a new PSM.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SP9030 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog