Fanuc alarm SP9049: HIGH CONVERTED DIFFERENTIAL SPEED

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

The difference between motor speed and the speed converted to spindle terms through the gear ratio exceeded the allowable value. In geared spindles the amplifier cross-checks both feedback sources; divergence means slipping, wrong ratio data or a feedback fault.

Likely causes

  • Gearbox slippage or clutch malfunction
  • Incorrect gear ratio parameters
  • Failure of either the motor sensor or spindle-side coder