Fanuc alarm SP9086: NO SPINDLE SENSOR 1-ROT SIGNAL
spindle alarm (serial spindle, alpha i) · Fanuc 0i-D
What it means
No one-revolution signal is being produced by the external spindle sensor at all. Without this once-per-turn pulse the spindle cannot establish its absolute angular reference, disabling orientation, threading and Cs operations.
Likely causes
- Disconnected or broken sensor cable
- Dead sensor head or grossly excessive sensing gap
- Target/mark feature missing, obscured or incorrectly machined
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A02B-0200-K8xx
Spindle sensor feedback cable · Check if others ruled out