Fanuc alarm SP9088: COOLING FAN ON RADIATOR STOPPED (SPM FAULTY)
spindle alarm (serial spindle, alpha i) · Fanuc 0i-D
What it means
The external radiator cooling fan of the spindle amplifier stopped, detected by its rotation sensor. This fan cools the finned heat sink carrying power-device losses, so the amplifier shuts down to prevent thermal destruction.
Likely causes
- Failed radiator fan motor or bearing
- Fan wiring/connector fault
- Fins and impeller clogged with dust swarf
Triage note: Replace the fan assembly; clean the heat sink while in there.