RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SP9088

Fanuc alarm SP9088: COOLING FAN ON RADIATOR STOPPED (SPM FAULTY)

spindle alarm (serial spindle, alpha i) · Fanuc 0i-D

What it means

The external radiator cooling fan of the spindle amplifier stopped, detected by its rotation sensor. This fan cools the finned heat sink carrying power-device losses, so the amplifier shuts down to prevent thermal destruction.

Likely causes

  • Failed radiator fan motor or bearing
  • Fan wiring/connector fault
  • Fins and impeller clogged with dust swarf

Triage note: Replace the fan assembly; clean the heat sink while in there.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SP9088 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog