Fanuc alarm STATUS1:30
βi SVPM · Fanuc αi/βi SVPM
What it means
Main circuit power module (IPM) detected an abnormal condition (βi SVPM/SVSP converter section).
Likely causes
- IPM/IGBT failure in converter stage
- Input supply imbalance
- SVPM internal control supply fault
Triage note: On combined βi SVPM units the whole module is normally exchanged - servo and spindle sections share one chassis.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A06B-6134-Hxxx
βi SVPM Combined Servo & Spindle Amplifier (rating-dependent) · Primary suspect
Need the part urgently?
Send us alarm STATUS1:30 with your machine details — typical RFQ turnaround is 24–48h.