RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / STATUS1:30

Fanuc alarm STATUS1:30

βi SVPM · Fanuc αi/βi SVPM

What it means

Main circuit power module (IPM) detected an abnormal condition (βi SVPM/SVSP converter section).

Likely causes

  • IPM/IGBT failure in converter stage
  • Input supply imbalance
  • SVPM internal control supply fault

Triage note: On combined βi SVPM units the whole module is normally exchanged - servo and spindle sections share one chassis.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6134-Hxxx

    βi SVPM Combined Servo & Spindle Amplifier (rating-dependent) · Primary suspect

    Request a quote →

Need the part urgently?

Send us alarm STATUS1:30 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog