RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / STATUS2:F

Fanuc alarm STATUS2:F: Inverter: radiator cooling fan stopped (servo unit)

αi/βi SVPM · Fanuc αi/βi SVPM

What it means

STATUS2 'F' on the βi SVPM indicates the cooling fan of the inverter radiator section has stopped, matching CNC alarm SV0601. Replace the fan before condemning the amplifier.

Likely causes

  • Seized or blocked radiator fan
  • Fan connector detached or faceplate not fully seated
  • Fan driver circuit failure

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm STATUS2:F with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog