Fanuc alarm SV0301: APC ALARM: n-TH AXIS COMMUNICATION ERROR

0i-D servo APC alarm · Fanuc 0i-D

What it means

Serial communication between CNC and absolute pulse coder failed (DTER/CRC class error) - position cannot be read

Likely causes

  • encoder feedback cable damaged/oil-soaked connector
  • pulse coder failure
  • servo amplifier side-board (interface) fault
  • noise from bundled power cables

Triage note: Wiggle-test/wiggle the connector while watching the alarm; if alarm follows cable movement replace cable, else swap pulse coder

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SV0301 with your machine details — typical RFQ turnaround is 24–48h.