What it means

The amount of positional deviation overflowed while the CNC was trying to establish machine position from the absolute detector, so a valid position could not be obtained. This is normally a parameter problem: the flexible feed gear ratio set in parameters No. 2084/No. 2085 does not match the actual machine mechanics. Verify the FFG numerator/denominator against the ball screw lead and gear ratio before replacing any hardware.

Likely causes

  • Incorrect flexible feed gear parameters No. 2084 / No. 2085
  • Parameter loss after memory failure followed by wrong re-entry
  • Mismatch between configured and actual detector resolution