Fanuc alarm SV0363: ABNORMAL CLOCK (INT)
αi/βi Servo (SV0xxx) · Fanuc 0i-D
What it means
The clock alarm occurred inside the built-in serial pulse coder, meaning the internal timing/reference clock used for serial data conversion failed its self-check. This is an internal encoder hardware fault; the encoder cannot produce trustworthy position data while it persists. Re-seating the feedback cable rules out connection issues, but recurrence means the pulsecoder must be replaced.
Likely causes
- Internal pulse coder oscillator/clock circuit failure
- Feedback cable or connector fault disrupting serial transfer
- Severe electrical noise at the encoder end
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- View part →
A860-2000-T301
pulse-coder · Common cause
- Request a quote →
A860-2070-T301
pulse-coder · Common cause
Need the part urgently?
Send us alarm SV0363 with your machine details — typical RFQ turnaround is 24–48h.