RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0420

Fanuc alarm SV0420: SYNC TORQUE EXCESS

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

In feed-axis synchronous control, the torque difference between master and slave axes exceeded the threshold in parameter No. 2031; only the master axis raises this alarm. Growing divergence in torque means the two mechanically coupled axes are fighting each other — usually from unequal friction, backlash, or one side losing feedback accuracy. Compare torque loads on both axes during motion to find the offender.

Likely causes

  • Unequal mechanical friction/guideway load between paired axes
  • Backlash or coupling wear on one side
  • Feedback discrepancy between master and slave detectors
  • Threshold parameter No. 2031 set too tight

Need the part urgently?

Send us alarm SV0420 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog