What it means

The difference between semi-closed (motor pulse coder) and full-closed (separate detector) feedback exceeded the limit in parameter No. 2118. Since both should track the same motion, divergence reveals slip or measurement error somewhere in the drivetrain — typically ballscrew-to-coupling slip, or scale misreading. Backlash measurement comparing motor position vs table position will localize the loss.

Likely causes

  • Coupling slippage between motor and ballscrew
  • Linear scale read head gap drift or tape damage
  • Accumulated mechanical backlash beyond threshold
  • Parameter No. 2118 set unrealistically tight (should be ~2–3x backlash)

Need the part urgently?

Send us alarm SV0421 with your machine details — typical RFQ turnaround is 24–48h.