RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0433

Fanuc alarm SV0433: INVERTER DC LINK LOW VOLTAGE

0i-D servo alarm (power circuit) · Fanuc 0i-D

What it means

DC link bus voltage dropped below threshold - reported from converter/power supply (PSM/PSU) side

Likely causes

  • incoming phase loss / low AC supply
  • pre-charge resistor or MCC contactor failure in PSM
  • loose DC link bus bars between modules
  • PSM internal charging circuit failure

Triage note: Measure all three input phases UNDER LOAD; chattering MCC or blown pre-charge resistor = replace power supply module, not the SVMs

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SV0433 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog