Fanuc alarm SV0438

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

Inverter: abnormal motor current alarm (axis identified by amplifier LED detail).

Likely causes

  • Power lead phase-to-phase short or ground fault
  • Motor winding short / insulation breakdown
  • Incorrect motor ID setting
  • SVM inverter failure

Triage note: Field guides (TIE, MRO): megger leg-to-leg and leg-to-ground, min 1Mohm at 500V; alarm persisting with leads disconnected = amplifier. One of the two most common Fanuc drive-failure presentations.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6114-H2xx / A06B-6130-H2xx

    Servo Amplifier Module (αi SVM or βi SVU, rating-dependent) · Primary suspect

    Request a quote →
  • A06B-02xx/03xx-Bxxx / A06B-0051-Bxxx

    Servo Motor (αi/βi series) · Common cause

    Request a quote →
  • Motor power lead set

    Motor Power Cable · Common cause

    Request a quote →