RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0439

Fanuc alarm SV0439

βi SVU/SVM · Fanuc βi SVU/SVM

What it means

Converter: DC link overvoltage.

Likely causes

  • Regenerated energy not absorbed (deceleration too fast for regen capability)
  • External/internal regen resistor open circuit
  • Converter overvoltage-sense circuit failure

Triage note: Measure regen resistor continuity first; open resistor is the dominant field cause. αi equivalent: PSM 07.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • βi regenerative resistor unit per machine spec

    Regenerative Resistor Unit · Primary suspect

    Request a quote →
  • A06B-6130-H2xx

    βi Servo Amplifier Unit SVU · Check if others ruled out

    Request a quote →

Need the part urgently?

Send us alarm SV0439 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog