RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0441

Fanuc alarm SV0441

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

Current offset error - offset value of the current detector (equivalent to emergency-stop current) abnormally high.

Likely causes

  • Current detector (shunt/hall sensing) failure inside amplifier
  • Amplifier control PCB analog front-end failure
  • Persistent after clean power cycle = hardware fault confirmed

Triage note: B-65285EN 3.3.8 Action 3: if alarm persists after power OFF/ON the current detector is faulty; for the αi series replace the amplifier. Unambiguous replace-the-amp indicator.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6114-H2xx / A06B-6130-H2xx

    Servo Amplifier Module (rating-dependent) · Primary suspect

    Request a quote →

Need the part urgently?

Send us alarm SV0441 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog