Fanuc alarm SV0443: INVERTER COOLING FAN FAILURE (PS SIDE)
0i-D servo alarm (cooling) · Fanuc 0i-D
What it means
Internal cooling fan of power supply/converter stopped (SV0444 = SVM fan)
Likely causes
- fan bearing worn out (top field failure)
- fan connector unplugged
- fan driver circuit on amp
Triage note: Cheapest fix in this dataset - fans are consumables; spin-test by hand and swap fan before considering the amplifier bad
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A290-0703-X277
Amplifier Internal Cooling Fan · Primary suspect
- Request a quote →
A06B-6210-H006
Power Supply Module (if fan driver dead) · Check if others ruled out