RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0444

Fanuc alarm SV0444: INV. COOLING FAN FAILURE

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

The internal cooling fan of the servo amplifier has stopped. Heat sinks rely on this fan to dissipate switching losses; running without it risks cascading into overheat alarms or semiconductor damage. Fans are consumables — replace the fan cartridge, clean the filter/ducts, and verify the fan connector is properly seated.

Likely causes

  • Fan bearing wear/end of life
  • Fan connector unseated or wiring broken
  • Blocked airflow (dust, swarf, clogged filter)
  • Fan drive circuit failure on control board

Triage note: Fan cartridges are user-replaceable on αi/βi units; match the amplifier model for the correct part.

Need the part urgently?

Send us alarm SV0444 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog