RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0446

Fanuc alarm SV0446: HARD DISCONNECT ALARM

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

Hardware-level detection found the built-in pulse coder disconnected — the amplifier stopped receiving feedback pulses entirely, not merely corrupted ones. Check the feedback cable seating at the motor rear cover and at the amplifier first; broken conductors inside the cable near flexing points are frequent. If a known-good cable doesn't clear it, the pulse coder has failed.

Likely causes

  • Feedback cable unplugged, cut, or broken at flex point
  • Connector pin damage/retraction at motor or amplifier end
  • Built-in pulsecoder failure
  • Missing feedback supply from amplifier side

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm SV0446 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog