RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0449

Fanuc alarm SV0449

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

Inverter: IPM alarm - intelligent power module latched an overcurrent/short event.

Likely causes

  • IPM/IGBT power stage destroyed
  • Motor power lead short or ground fault
  • Motor winding short
  • SVM control-board gate-driver failure

Triage note: Always isolate motor/leads before installing the replacement - a shorted motor will kill the new SVM immediately.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • A06B-6114-H2xx / A06B-6127-H2xx / A06B-6132-H2xx

    Servo Amplifier Module (series + rating dependent) · Primary suspect

    Request a quote →
  • IPM power module per rating

    IGBT Module · Check if others ruled out

    Request a quote →
  • Motor power lead set

    Motor Power Cable · Common cause

    Request a quote →

Need the part urgently?

Send us alarm SV0449 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog