Fanuc alarm SV0449
αi/βi Servo (SV0xxx) · Fanuc 0i-D
What it means
Inverter: IPM alarm - intelligent power module latched an overcurrent/short event.
Likely causes
- IPM/IGBT power stage destroyed
- Motor power lead short or ground fault
- Motor winding short
- SVM control-board gate-driver failure
Triage note: Always isolate motor/leads before installing the replacement - a shorted motor will kill the new SVM immediately.
Replacement parts
We supply the following units for this alarm — tested, warranty-backed:
- Request a quote →
A06B-6114-H2xx / A06B-6127-H2xx / A06B-6132-H2xx
Servo Amplifier Module (series + rating dependent) · Primary suspect
- Request a quote →
IPM power module per rating
IGBT Module · Check if others ruled out
- Request a quote →
Motor power lead set
Motor Power Cable · Common cause