Fanuc alarm SV0471: n AXIS:SPC SOFT DISCONNECT (MNT)

safety/dual-check alarm · Fanuc 30i/31i/32i-B

What it means

The monitor CPU detected a pulse coder (serial feedback) signal error on axis n while cross-checking against the CNC CPU channel. Both channels read the same encoder; a discrepancy or broken feedback trips this safety alarm and stops the axis immediately. Remedy per Fanuc is replacement of the pulse coder.

Likely causes

  • Serial pulse coder failure
  • Feedback cable damage or noise on the JF1 leg
  • Loose connector at the amplifier or coder

Triage note: Counterpart alarm SV0453 is the same detection made by the CNC (control) side.