RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Fanuc / SV0488

Fanuc alarm SV0488: SAFE TEST OVER TIME

safety/dual-check alarm · Fanuc 30i/31i/32i-B

What it means

A scheduled MCC off Test - the mandatory periodic exercise of both MCC shutoff paths in the dual-channel safety system - did not complete within the time set in parameter No.1946. The safety outputs must prove they can kill motor power; a timeout means the shutoff path is compromised. Fanuc directs you to inspect the MCC contactor.

Likely causes

  • Welded, worn or slow MCC contactor contacts
  • Open circuit between MCF output, contactor coil and *SMC feedback
  • Parameter No.1946 window too short for the contactor used

Triage note: Dual Check Safety alarms cannot be cancelled by reset; cycle power after repair.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • Main circuit magnetic contactor (MCC), machine-builder specific

    unit · Common cause

    Request a quote →

Need the part urgently?

Send us alarm SV0488 with your machine details — typical RFQ turnaround is 24–48h.