Fanuc alarm SV0600: INV. DC LINK OVER CURRENT

αi/βi Servo (SV0xxx) · Fanuc 0i-D

What it means

Excessive current was measured flowing in the amplifier's DC link. Overcurrent on the bus typically reflects a short or severe overload downstream of the bus — in the inverter section, motor windings, or power cabling. Megger-check motor and power leads and inspect for coolant ingress before assuming amplifier failure.

Likely causes

  • Motor winding short or insulation breakdown
  • Power line phase-to-phase short or crushed cable
  • Inverter transistor module failure
  • Instantaneous extreme load spike