What it means

Inverter: FSSB fiber communication error on COP10B side - unit failing to receive data from CNC/master direction.

Likely causes

  • COP10B optical fiber cable failure (cable nearest the affected unit)
  • SVM optical interface failure
  • Upstream SVM COP10B-side failure
  • CNC servo card failure

Triage note: B-65285EN 3.2.12: replace the COP10B cable first, then the SVM nearest the CNC, then the CNC servo card. Brief U blink at power-on followed by steady '-' is normal, not a failure.

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

  • COP10A/B FSSB optical fiber cable

    FSSB Optical Fiber Cable · Primary suspect

    Request a quote →
  • A06B-6114-H2xx

    Servo Amplifier Module αiSVM (unit nearest CNC showing U) · Common cause

    Request a quote →

Need the part urgently?

Send us alarm U with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteFanuc catalog