RFQ turnaround 24–48h · inbound queries only
Home / Alarm Library / Siemens / 1

Siemens alarm 1: Battery: Data loss at power off!

SINUMERIK 840C legacy alarm · Siemens 840C

What it means

The NCK/PLC backup battery is empty, so buffered data is no longer battery-backed. During operation production may continue, but switching off means total data loss and obligatory re-installation of the whole NCK/PLC unit. The battery must be replaced while the control is switched on.

Likely causes

  • Backup battery fully discharged
  • Battery replaced with control switched off
  • Corroded battery holder contacts

Replacement parts

We supply the following units for this alarm — tested, warranty-backed:

Need the part urgently?

Send us alarm 1 with your machine details — typical RFQ turnaround is 24–48h.

Request a QuoteSiemens catalog